Ghulam
Control Room Operator
Kurdistan
Summary of Career
1. Power plant operator
2. Control room operator
3. Control room supervisor
4. Power plant operation
5. Power plant management
6. Power plant commissioner
7. Start up and shutdown
8. Trouble shooting
9. Black outs
10. Walkdowns
? Emergency handle while fire in turbine compartment. ? Frame 9e 500MW power plant Commissioning and start up ? Thermal power plant Commissioning and Testing ? TM2500 Gas turbine commissioning and Testing ? Gas pipe line commissioning and testing.
Experience as Control Room Operator/Shift Supervisor
07 July 2017
Directs the activities of the assigned personnel involved in the operation/maintenance of various utilities equipment
related to electrical power plant.
Operates and/or ensures the operation of various power utilities equipment in the central power plant is carried out
safely as per the standard instructions, such as; gas turbine, generator, transformers, high voltage alternators, …etc.
Operates fire and gas system and takes immediate action in the event of alarm, false alarm or system malfunctioning.
Checks the functioning of rotating machinery and analyses data collected for performance improvement and efficient
operations.
Monitors fuel gas consumption and ensures adequate supply of fuel gas to the turbines.
Monitors plant parameters through DCS screen display, diagnoses faults and takes corrective action for all equipment
on power plant to prevent major shut-down which can cause major impact Grid station
? Makes appropriate adjustments to various instruments, turbines and alternator such as speed, operations frequency
etc.. to synchronize indicators and ensures smooth operation.
? Monitors variables and corrects control setting on valve opening to maintain proper functioning of plant and operation
standards temperatures, pressures and cooling water flow rates.
? Logs all reading at fixed intervals in a log book, Investigates causes of failure in emergencies and acts promptly to
rectify the same. Maintains safety of equipment and takes corrective action in case of abnormalities.
? Carries out planned inspection on power generation facilities and equipment and ensures maintaining proper
housekeeping standard in the plant.
? Directs and guides contracted maintenance personnel when carrying out work in the Power Platform or
commissioning the Plant after major overhaul and installation of new equipment
? Daily contacts with Electrical Supervisor, Platform Supervisors, CCR Supervisors and Electrical, Mechanical and
Instrument Maintenance personnel to discuss problems and requirements related to Electrical, Mechanical, and
Instrument and Utilities equipment.
? Frequent contacts with other disciplines up to Team Leader’s level to supply, increase and decrease the level of
utilities. Works according to Company’s established policies, guidelines and specialized standards.
? Takes initiatives during emergency situations, as failure will lead to blackout and process plant shutdown.
? Completed work is subject to review by Supervisor.
Experience as field operator/Control Room Operator
07 March 2019
22 July 2017
1: Comply with safety rules and regulations. Be familiar with the fire equipment in area.
Follow the instructions of the Shift Supervisor/Shift Charge Engineer and CCR Operator.
2: Familiar with plant P&IDs, SOPs, Work instructions, basic control logics as well as the emergency operation
procedures and any other related documents.
3: Monitor all parameters and enter periodic readings on log sheets. Summarize all activities/events that
Took place during shift in the log book.
4: Inspect the area and auxiliaries during the shift to make sure that all equipment parameters are within limits.
Report abnormalities to the CCR Operator.
5: Perform equipment change over according to preset schedules. Raise work requests or defect notes for faulty
equipment.
6: Coordinate with CCR Operator/Shift Supervisor for isolating and lining up the equipment’s and system before andafter maintenance. Maintain a tidy housekeeping in the work area and ensure clean up after maintenance work.
7: Follow standard operating procedures and work instructions
8: Assist in the training and familiarization of new operators.
9: Report near misses and implement prescribed risk controls.
10: Report deviations in Quality, Health, Safety and Environmental Management System.
11: Ensure proper waste disposal measures.
12: Perform other duties as assigned.
Experience as Control Room Operator
01 July 2015
28 February 2016
? Carried out Gas Turbine commissioning including lube-oil filling, flushing, over speed test, Overload test, Full Speed
No Load test, Reverse and Reactive Power test, Generator Differential test and Control System testing.
? Carry out plant start-ups, shut downs, observe and report Turbine performance on different Fuel.
? Developed operational procedures, operational log sheets, shifts first hour checklists, shut down job lists
? Lead operation team in plant emergencies like sudden equipment failure, sudden increase/decrease of load on turbine,
tripping, failures in Electrical systems and power black outs
? Coordination with customer plants for load management and synchronization
? Prepare daily production report, monthly performance report, evaluating performance factors on daily basis and
drafting incident reports
? Compliance with PTW system, ensuring electrical and process isolations for the job, following Safety Critical
Device/System Defeat protocol for the job
? Liaison with safety in planning for fire drills, evacuation plans, implementing JSAs and correct use of PPEs
? Conduct meetings with EPC for about day to day issues and objection and contradictions as per standards
? Prepared the Punch Lists and followed up on them with EPC contractor during project stage
Experience as Control Room Operator
Engro Powergen Limited - Pakistan
01 November 2014
31 July 2015
? 3 Gas Turbines (duel fuel), 25MW GE Model TM2500 with Wood Ward control system
? Commissioning of GT systems
? Responsible for All test related with Gas turbine system
? Responsible for operation of Power plant including system
? Bentley Nevada vibration system
? Liquid fuel oil and gas fuel system
? Water injection system
? 11 KV switchgear from Siemens
? 1 MBH 2500KVA BSGD for back up
Experience as Control Room Operator
Albario Engineering
01 July 2013
31 October 2019
? Take charge from previous shift,
? Read the log book, check all the parameters of plant,
? Reporting to Sr. Shift Charge Engineer for any abnormality or change in parameters,
? Carry out regular detailed inspection of all rotating equipment such as turbines, generators, electric moto
pumps, compressors etc. and stationary equipment’s such as vessels, tanks, heat exchangers etc. to ensure
accurate and proper functioning, observed any abnormality like leakage abnormal sound and to inforSSCE,
? Routine inspection of automation rooms and switch gear rooms
? Inspection of Fire Fighting equipment’s (fixed and portable)
? Prepare equipment’s for maintenance activities such as electric isolation, manual isolation, Depressurizatioand draining.
Experience as Field Operator
TNB Liberty Power Limited
01 August 2010
22 May 2013
Machine & Equipment’s Handled:-
? Gas Turbine model V94.2 Siemens (155MW) with respective auxiliaries,
? Steam Turbine ABB (80MW) with respective auxiliaries,
? Dual Pressure HRSG forced circulation made by CMI.
To perform Safe Startup, Shutdown and normal Operation of Plant having:-
? Take charge from previous shift,
? Read the log book, check all the parameters of plant,
? Reporting to Sr. Shift Charge Engineer for any abnormality or change in parameters,
? Carry out regular detailed inspection of all rotating equipment such as turbines, generators, electric motors,
pumps, compressors etc. and stationary equipment’s such as vessels, tanks, heat exchangers etc. to ensure
accurate and proper functioning, observed any abnormality like leakage abnormal sound and to informSSCE,
? Routine inspection of automation rooms and switch gear rooms
? Inspection of Fire Fighting equipment’s (fixed and portable)
? Prepare equipment’s for maintenance activities such as electric isolation, manual isolation, Depressurizationand draining.
Bachelor 01 May 2012
B.Tech pass